Hydraulic Design of Spillways
Technical Engineering and Design Guides, as adapted from the U.S. Army Corps of Engineers, No. 12. This manual presents guidance for the hydraulic...

Performance of Deep Foundations Under Seismic Loading
This proceedings, Performance of Deep Foundations Under Seismic Loading, consists of papers presented at a session of the 1995 ASCE Annual...

So Your Home Is Built on Expansive Soils
Prepared by the Shallow Foundations Committee of the Geotechnical Division of ASCE. This report assists homeowners in understanding why expansive soils...

Do Civil Engineers Have an Ethical Responsibility to their Client at the Expense of the Environment?
The application of engineering ethics to the environment is at the center of the debate regarding sustainable development. If the environment is to be held above client needs, say many,...

The Foundation for a New Approach to Implement Building Innovation
Prepared by the Partnership for Building Innovation project, which is sponsored by CERF; National Institute of Standards and Technology; U.S. Department of Housing and Urban Development;...

Checking Concrete Growth
When the Tennessee Valley Authority built its dams in the 1930s, instrumentation installed in the massive concrete detected a defect that would later cause major problems: concrete growth...

Design of Mat Foundation for Egg Shape Digesters
Two levels of ground motion, the Maximum Probable Earthquake and the Maximum Credible Earthquake, were considered in designing the 2.5 million gallon egg shape digesters and their combined...

Coupling Translation and Rocking Motions
In the design of concrete block foundations for rotating and reciprocating machines, it is important to avoid resonant conditions. Therefore, accurate determination of the frequencies...

Case Study - Performance of Diaphragm Walls During Construction; Predictions vs. Field Measurements
Rigid diaphragm walls (slurry walls) are being used more than any other earth supporting system for underground construction projects in confined downtown sites throughout the United States...

Seismic Evaluation of the Tied-arch Bridge Across the Mississippi River on I-40
The bridge reported in this paper is a two-span steel tied-arch bridge supported on massive caisson foundations. Site specific seismic studies were carried out to establish the ground...

Site Effects on Strong Shaking and Seismic Risk: Recent Developments and Their Impact on Seismic Design Codes and Practice
The very strong influence of localized poor or 'adverse' geological/geotechnical foundation conditions on patterns and concentrations of damage during a number of recent earthquakes (e.g.:...

Guide for the Design of Prestressed Concrete Poles
With the aim of providing engineers with some basic tools and guidelines for the design of structures, the committee prepares code and policy changes, and to expand input of manufacturers...

Overview - Electrical Substation Structures Design Guide
The ASCE Substation Structures subcommittee of the Committee on Electrical Transmission Structures (CETS) is developing a substation structures design guide. The guide discusses the analysis...

SDC Detector Foundation Requirements for the SSC
The Solenoidal Detector Collaboration (SDC) detector weighs approximately 32,000 metric tons, and its ability to perform to design specifications is directly related to its internal alignment....

High-Strain Kinetic Testing of Deep Foundations
High-strain kinetic testing involves the upward decelerating or accelerating of a mass and using its inertial force to axial prolonged pulse at the head of a pile. Currently available...

Interpretation of Nondestructive Integrity Tests Using Artificial Neural Networks
A barrier to more frequent use of nondestructive integrity tests on cast-in-place foundations is the difficulty of interpreting the test results to identify the presence or absence of...

Messeturm Tower: Frankfurt, Germany
A 256 meter (840 feet)tall office tower, currently the tallest building in Europe, has been constructed in Frankfurt Germany. The 7- story structure with 85500 square meter (920,000 square...

The Structural History of the Jacob Bachmann Tavern
The Jacob Bachmann Tavern is located in Easton, Pennsylvania. It is a collection of four interconnected buildings that have been constructed and modified over a period of 240 years. Structural...

Seismic Performance and Retrofit of the Golden Gate Bridge
Since its opening in 1937, the Golden Gate Bridge has endured and functions as an important transportation link for Bay Area commerce and commuters. After an earthquake in 1989, T.Y. Lin...

Akashi-Kaikyo Bridge Underconstruction
This paper presents 1) brief history of the survey work, 2) brief description of the physical dimensions and structural system, 3) major studies for the design, 4) development of higher...

 

 

 

 

Return to search